Pagina 2

6Icon OverviewThe following section summarizes the icons that are commonly used in the DataC-ollector. At the bottom of the Home Window there is a

Pagina 3 - Table of Contents

7DATACOLLECTOR USER’S GUIDEWhile conducting an experiment, a status bar is shown at the top ofthe screen. The status bar contains buttons to easily ac

Pagina 4

8Indicates a continuous experiment. Data collection continues until user manually stops experiment. See “Rate” on page 16.Indicates the data set is

Pagina 5 - Chapter 1: Introduction

9DATACOLLECTOR USER’S GUIDEChapter 5: Data Collection ModeData Collection Mode is used to collect, record and analyze data. After selecting“Data Coll

Pagina 6 - Chapter 2: Kit Contents

10Alternatively, you may choose to open an old experiment. This is done by tappingFiles at the bottom of the Go! Window.Data Collection: Meter WindowO

Pagina 7 - Chapter 3: Getting Started

11DATACOLLECTOR USER’S GUIDETo resume the experiment, push the Go button on the enclosure.When the experiment is resumed, the last readings will disap

Pagina 8 - Port Identification

12Data Collection: Graph WindowThe Graph Window (Figure 8) graphs data from the current experiment using set-tings from the Table Window. If the exper

Pagina 9

13DATACOLLECTOR USER’S GUIDEFigure 9: Data Collection: Graph Window - Full ScreenData Collection: Setup WindowIn the Setup Window (Figure 10), you wil

Pagina 10 - Icon Overview

14After selecting “Modify”, you will see the following window.Figure 11: Data Collection: Modify Setup WindowFrom here, you can change the file name,

Pagina 11 - ATACOLLECTOR USER’S GUIDE

15DATACOLLECTOR USER’S GUIDEFigure 12: Data Collection: Rename Experiment WindowModeThere are two different types of experiments you can run: Interval

Pagina 12

Copyright © 2009 CPO Science9/09DataCollector designed by: Thomas S. Narroin conjunction with: PRIDarren Garnier

Pagina 13 - Starting an Experiment

16Rate The Rate setting controls how often the DataCollector takes measurements inStandard Mode. The DataCollector has rates from 1 - 2,000 Hz. The

Pagina 14 - Data Collection: Meter Window

17DATACOLLECTOR USER’S GUIDEChapter 6: CPO Timer ModeOverview of Functions and FeaturesCPO Timer Mode works like the CPO Timer for photogate and Sound

Pagina 15 - Data Collection: Table Window

18The Reset button, at the bottom of the window, is used to clear all readings, andresets the current value to zero. The Memory button is a feature av

Pagina 16 - Data Collection: Graph Window

19DATACOLLECTOR USER’S GUIDEFigure 14: Time Intervals and PhotogatesFrequency FunctionIn CPO Timer Mode, the DataCollector can measure the frequency o

Pagina 17 - Data Collection: Setup Window

20• the frequency of a vibrating string• the RPM of the CPO Science Electric Motor or Ripcord GeneratorPeriod FunctionThe Period Function measures the

Pagina 18

21DATACOLLECTOR USER’S GUIDEChapter 7: Meter ModeIn Meter Mode, current values for sensors are displayed, as well as the experimentclock. No data is

Pagina 19

22Chapter 8: Stopwatch ModeIn Stopwatch Mode, the DataCollector functions solely as a stopwatch. The Stop-watch icon in the status bar indicates you a

Pagina 20

23DATACOLLECTOR USER’S GUIDEChapter 9: Interval vs. Standard ModeInterval Mode experiments use photogates, or other digital sensors, to record timeint

Pagina 21 - Chapter 6: CPO Timer Mode

24IMPORTANT: The DataCollector will record a maximum of three sensors. If you choose to record two digital signals (Pho-togate A and B) in Standard M

Pagina 22 - Interval Function

25DATACOLLECTOR USER’S GUIDEChapter 10: Connecting to a Com-puterThe DataCollector is designed so that you can easily connect the unit to a com-puter

Pagina 23 - Frequency Function

Table of ContentsIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Kit Co

Pagina 24 - Count Function

26computer using the included USB cable. Your computer should automatically rec-ognize the device. Next, simply drag and drop the software file from

Pagina 25 - Chapter 7: Meter Mode

27DATACOLLECTOR USER’S GUIDEChapter 11: Warnings and PrecautionsPlease make note of the following warnings and precautions. Failure to followthese gui

Pagina 26 - Chapter 8: Stopwatch Mode

Warranty InformationCPO Science warranties this instrument against defects in materials and workmanship for a period of one year. Repair and/or replac

Pagina 27 - Standard Mode

Updating the Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Warnings and Precaution

Pagina 28 - Choosing a Mode

1DATACOLLECTOR USER’S GUIDEChapter 1: IntroductionThe CPO Science DataCollector is a device used to easily view and record datafrom various sensors, i

Pagina 29 - Updating the Software

2Chapter 2: Kit ContentsThere are two different configurations of the DataCollector available. These aresummarized in the table below.Table 1: DataC

Pagina 30

3DATACOLLECTOR USER’S GUIDEChapter 3: Getting StartedUse the following diagrams and information to familiarize yourself with the CPOScience DataCollec

Pagina 31

4Figure 3: DataCollector Port IdentificationPort IdentificationThe DataCollector has six ports on the rear of the enclosure, shown in Figure 3. The a

Pagina 32

5DATACOLLECTOR USER’S GUIDEChapter 4: Using the DataCollectorStarting the DataCollector ApplicationAfter powering on the DataCollector as described in